General Requirements for Communications Systems
Summary
Chapter 8 general rules for communications — entrance, protection, grounding/bonding of communications systems.
Chapter 8 is independent of Chapters 1–7 except where specifically referenced (90.3).
- Comms bonding often uses a bonding conductor to the intersystem bonding termination.
- Primary protectors at aerial/underground entrances.
- Independence from Ch. 1–7 is a core 90.3 fact.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (39)
- 800.1Scope
- 800.2Definitions
- 800.3Other Articles
- 800.18Installation of Equipment
- 800.21Access to Electrical Equipment Behind Panels Designed to Allow Access
- 800.24Mechanical Execution of Work
- 800.25Abandoned Cables
- 800.26Spread of Fire or Products of Combustion
- 800.27Temperature Limitation of Wires and Cables
- 800.44Overhead Communications Wires and Cables
- 800.47Underground Circuits Entering Buildings
- 800.48Unlisted Cables Entering Buildings
- 800.49Metal Entrance Conduit Grounding
- 800.50Circuits Requiring Primary Protectors
- 800.53Lightning Conductors
- 800.90Protective Devices
- 800.93Grounding or Interruption of Metallic Sheath Members of Communications Cables
- 800.100Cable and Primary Protector Bonding / Grounding (Communications)
- 800.106Primary Protector Grounding and Bonding at Mobile Homes
- 800.110Raceways for Communications Wires and Cables
- 800.113Installation of Communications Wires and Cables
- 800.133Installation of Communications Wires, Cables, and Equipment
- 800.154Applications of Listed Communications Wires and Cables and Communications Raceways
- Table 800.154(a)Applications of Listed Communications Wires, Cables, and Network-Powered Broadband Communications System Cables in Buildings
- Table 800.154(b)Applications of Listed Communications Raceways in Buildings
- Table 800.154(c)Applications of Listed Cable Routing Assemblies in Buildings
- Table 800.154(E)Cable Substitutions
- 800.156Dwelling Unit Communications Outlet
- 800.170Equipment
- 800.173Drop Wire and Cable
- 800.179Communications Wires and Cables
- Table 800.179Cable Markings
- 800.180Grounding Devices
- 800.182Communications Raceways
- Table 800.182(a)Cable Routing Assembly Markings
- Table 800.182(b)Communications Raceway Markings
- Figure 800.154(E)Cable Substitution Hierarchy
- Informational Note Figure 800.100(B)(1)Illustration of a Bonding Conductor in a Communications Installation
- Informational Note Figure 800.100(B)(2)Illustration of a Bonding Conductor in a Communications Installation
Practice questions (0)
No practice questions tagged to Article 800 yet.
Pictures

800.1 · Optical fiber cables can be installed

800.25 · Another unique feature of Chapter 8 is that common wiring

800.2 · Copyilghl 2020, www.MikeHollg)m

800.2 · The circuit that extends service

800.2 · Point of

800.2 · Illustration — NEC 800.2

800.3 · Electrical equipment with a metal enclosure, or a

800.21 · VIOLATION: Access to equipment must not be

800.21 · Behind Panels Designed to Allow Access

800.24 · Exposed cables must be supported by *.

800.25 · The ceiling-support wires or the ceiling

800.25 · Abandoned Cables