Fire alarm circuit classifications (NPLFA/PLFA), survivability, and separation.
- Fire alarm wiring methods differ from ordinary Class 2.
- Survivability levels for pathway integrity.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (38)
- 760.1Scope
- 760.2Definitions
- 760.3Other Articles
- 760.21Access to Electrical Equipment Behind Panels Designed to Allow Access
- 760.24Mechanical Execution of Work
- 760.25Abandoned Cables
- 760.30Fire Alarm Circuit Identification
- 760.32Fire Alarm Circuits Extending Beyond One Building
- 760.35Fire Alarm Circuit Requirements
- 760.41NPLFA Circuit Power Source Requirements
- 760.43NPLFA Circuit Overcurrent Protection
- 760.45NPLFA Circuit Overcurrent Device Location
- 760.46NPLFA Circuit Wiring
- 760.48Conductors of Different Circuits in Same Cable, Enclosure, or Raceway
- 760.49NPLFA Circuit Conductors
- 760.51Number of Conductors in Cable Trays and Raceways, and Derating
- 760.53Multiconductor NPLFA Cables
- 760.121Power Sources for PLFA Circuits
- 760.124Circuit Marking
- 760.127Wiring Methods on Supply Side of the PLFA Power Source
- 760.130Wiring Methods and Materials on Load Side of the PLFA Power Source
- 760.133Installation of Conductors and Equipment in Cables, Compartments, Cable Trays, Enclosures, Manholes, Outlet Boxes, Device Boxes, and Raceways for Power-Limited Circuits
- 760.135Installation of PLFA Cables in Buildings
- 760.136Separation from Electric Light, Power, Class 1, NPLFA, and Medium-Power Network-Powered Broadband Communications Circuit Conductors
- 760.139Installation of Conductors of Different PLFA Circuits, Class 2, Class 3, and Communications Circuits in the Same Cable, Enclosure, Cable Tray, or Raceway
- 760.142Conductor Size
- 760.143Support of Conductors
- 760.145Current-Carrying Continuous Line-Type Fire Detectors
- 760.154Applications of Listed PLFA Cables
- Table 760.154Applications of Listed PLFA Cables in Buildings
- Table 760.154(A)Cable Substitutions
- Table 760.154(D)Cable Substitutions
- 760.176Listing and Marking of NPLFA Cables
- Table 760.176(G)NPLFA Cable Markings
- 760.179Listing and Marking of PLFA Cables and Insulated Continuous Line-Type Fire Detectors
- Table 760.179(I)Cable Markings
- Figure 760.154(A)Cable Substitution Hierarchy
- Figure 760.154(D)Cable Substitution Hierarchy
Practice questions (0)
No practice questions tagged to Article 760 yet.
Pictures

760.21 · Fire Alarm Cable, 760.21

760.2 · Art. 770 = Orange

760.2 · Cables not terminated

760.2 · Cable legend

760.121 · NEC Chapter 9, Table 1 2(A)

760.24 · Behind Panels Designed to Allow Access

760.21 · PLFA cables can be installed in communications raceways

760.25 · The accessible portion of cabl

760.30 · Circuits

760.30 · Cable Legend

760.30 · The branch circuit that supplies PLFA

760.1 · Conductors and equipment on the supply side of the power-limited fire
Article 760 chat
- No messages yet — start the conversation.