Class 1, Class 2, and Class 3 Remote-Control, Signaling, and Power-Limited Circuits
Summary
Power-limited circuit classes — separation from power conductors, cable types CL2/CL3, and reclassification.
Class 2 is the everyday thermostat/data-power world.
- Class 2 energy limited — different from power wiring.
- Separation rules when sharing raceways/cables.
- Do not substitute power cable casually for CL2 unless permitted.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (39)
- 725.1Scope
- 725.2Definitions
- 725.3Other Articles
- 725.21Access to Electrical Equipment Behind Panels Designed to Allow Access
- 725.24Mechanical Execution of Work
- 725.25Abandoned Cables
- 725.30Class 1, Class 2, and Class 3 Circuit Identification
- 725.31Safety-Control Equipment
- 725.35Class 1, Class 2, and Class 3 Circuit Requirements
- 725.41Class 1 Circuit Classifications and Power Source Requirements
- 725.43Class 1 Circuit Overcurrent Protection
- 725.45Class 1 Circuit Overcurrent Device Location
- 725.46Class 1 Circuit Wiring Methods
- 725.48Conductors of Different Circuits in the Same Cable, Cable Tray, Enclosure, or Raceway
- 725.49Class 1 Circuit Conductors
- 725.51Number of Conductors in Cable Trays and Raceway, and Derating
- 725.52Circuits Extending Beyond One Building
- 725.121Power Sources for Class 2 and Class 3 Circuits
- 725.124Circuit Marking
- 725.127Wiring Methods on Supply Side of the Class 2 or Class 3 Power Source
- 725.130Wiring Methods and Materials on Load Side of the Class 2 or Class 3 Power Source
- 725.133Installation of Conductors and Equipment in Cables, Compartments, Cable Trays, Enclosures, Manholes, Outlet Boxes, Device Boxes, and Raceways for Class 2 and Class 3 Circuits
- 725.135Installation of Class 2, Class 3, and PLTC Cables
- 725.136Separation from Power and Class 1 Conductors
- 725.139Installation of Conductors of Different Circuits in the Same Cable, Enclosure, or Raceway
- 725.141Installation of Circuit Conductors Extending Beyond One Building
- 725.143Support of Conductors
- 725.144Transmission of Power and Data
- Table 725.144Ampacities of Each Conductor in Amperes in 4-Pair Class 2 or Class 3 Balanced Twisted-Pair Cables Based on Copper Conductors at an Ambient Temperature of 30°C (86°F) with All Conductors in All Cables Carrying Current, 60°C (140°F), 75°C (167°F), and 90°C (194°F) Rated Cables
- 725.154Applications of Listed Class 2, Class 3, and PLTC Cables
- Table 725.154Applications of Listed Class 2, Class 3, CMUC, and PLTC Cables in Buildings
- Table 725.154(A)Cable Substitutions
- Table 725.154(G)Cable Substitutions
- 725.170Listing and Marking of Equipment for Power and Data Transmission
- 725.179Listing and Marking of Class 2, Class 3, and Type PLTC Cables
- Table 725.179Cable Marking
- Table 725.179(J)Cable Marking
- Figure 725.154(A)Cable Substitution Hierarchy
- Informational Note Figure 725.121Class 2 and Class 3 Circuits
Practice questions (0)
No practice questions tagged to Article 725 yet.
Pictures

725.49 · (1) Identification. The power monitoring or energy management

725.1 · Chimes With

725.1 · Article 725 contains the requirements for remote-control, signaling,

725.2 · Remote-Control Circuit. Any electrical circuit that controls

725.2 · Class 2 Circuit. The portion of the wiring system between

725.3 · Other Articles

725.3 · Twenty-two 1 8 TFFN

725.3 · Cable legend

725.7 · Firestopping materials are listed for the specific types of wiring

725.8 · Visit International Firestop Council's website (www.firestop.org)

725.9 · Firestopping materials are listed for the specific types of wiring

725.21 · Class 2 cables can be installed in cable routing assemblies