Summary
PV array circuits, rapid shutdown, disconnects, grounding, and conductor sizing.
High-growth exam and field article.
- Rapid shutdown requirements protect first responders.
- DC circuits have special wiring and labeling.
- Interactive inverters interface with 705.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (59)
- 690.1Scope
- 690.2Definitions
- 690.3Other Articles
- 690.4Installation
- 690.5Ground-Fault Protection
- 690.6Alternating-Current (ac) Modules
- 690.7Maximum Voltage
- Table 690.7Voltage Correction Factors for Crystalline and Multicrystalline Silicon Modules
- Table 690.7(A)Voltage Correction Factors for Crystalline and Multicrystalline Silicon Modules
- 690.8Circuit Sizing and Current (PV)
- 690.9Overcurrent Protection
- 690.10Stand-Alone Systems
- 690.11Arc-Fault Circuit Protection (Direct Current)
- 690.12Rapid Shutdown of PV Systems on Buildings
- 690.13All Conductors
- 690.14Additional Provisions
- 690.15Disconnection of Photovoltaic Equipment
- 690.16Fuses
- 690.17Switch or Circuit Breaker
- 690.18Installation and Service of an Array
- 690.31Methods Permitted
- Table 690.31(A)(a)Correction Factors
- Table 690.31(A)(b)Ampacities of Insulated Conductors Rated Up To and Including 2000 Volts, 105°C Through 125°C (221°F Through 257°F), Not More Than Three Current-Carrying Conductors in Raceway, Cable, or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F)
- Table 690.31(C)Correction Factors
- Table 690.31(C)(4)Minimum PV Wire Strands
- 690.32Component Interconnections
- 690.33Connectors
- 690.34Access to Boxes
- 690.35Ungrounded Photovoltaic Power Systems
- 690.41System Grounding
- 690.42Point of System Grounding Connection
- 690.43Equipment Grounding
- 690.45Size of Equipment Grounding Conductors
- 690.46Array Equipment Grounding Conductors
- 690.47Grounding Electrode System
- 690.48Continuity of Equipment Grounding Systems
- 690.49Continuity of Photovoltaic Source and Output Circuit Grounded Conductors
- 690.50Equipment Bonding Jumpers
- 690.51Modules
- 690.52Alternating-Current Photovoltaic Modules
- 690.53Direct-Current Photovoltaic Power Source
- 690.54Interactive System Point of Interconnection
- 690.55Photovoltaic Power Systems Employing Energy Storage
- 690.56Identification of Power Sources
- 690.57Load Disconnect
- 690.59Connection to Other Sources
- 690.60Identified Interactive Equipment
- 690.61Loss of Interactive System Power
- 690.62Ampacity of Neutral Conductor
- 690.63Unbalanced Interconnections
- 690.64Point of Connection
- 690.71Installation
- 690.72Charge Control
- 690.74Battery Interconnections
- 690.80General
- 690.85Definitions
- Figure 690.1(a)Informational Note Figure 690.1(a) Identification of PV Power Source Components
- Figure 690.1(b)Informational Note Figure 690.1(b) Identification of PV System Components in Common Configurations
- Figure 690.56(C)Informational Note Figure 690.56(C) Label for Roof-Mounted PV Systems with Rapid Shutdown
Practice questions (2)
1.PV circuit current used for conductor sizing is generally 125% of the module Isc (or the calculated 690.8 current), and conductors are then sized so that the OCPD is not less than that current.
2.PV system dc circuits on or in a building generally require a rapid-shutdown function as specified in 690.12.
Pictures

690.1 · Scope

690.2 · AC Module Inverter

690.2 · PV supply stations and are for the sole purpose of providing electric

690.2 · The definitions in this section only apply within this article.

690.2 · Scale e,:V:,c (

690.2 · Alternating-current modules are connected in parallel with

690.2 · Alternating-Current Module

690.2 · Mentally protected unit consisting of solar cells, inverter, and other

690.2 · A device that can provide an output de

690.2 · PV Source

690.2 · An enclosure that includes devices

690.2 · Solar Cell