Swimming Pools, Fountains, and Similar Installations
Summary
Pools/spas — equipotential bonding, clearances for lights/receptacles, GFCI, and underwater luminaires.
Top residential exam article.
- Equipotential bonding grid is not the same as equipment grounding alone.
- Receptacle distances from pool walls are fixed exam numbers.
- Underwater lights have low-voltage and GFCI rules.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (64)
- 680.1Scope
- 680.2Definitions
- 680.3Other Articles
- Table 680.3Other Articles
- 680.4Approval of Equipment
- 680.5Ground-Fault Circuit Interrupters
- 680.6Grounding
- 680.7Cord-and-Plug-Connected Equipment
- 680.8Overhead Conductor Clearances
- Table 680.8Overhead Conductor Clearances
- 680.9Electric Pool Water Heaters
- Table 680.9(A)Overhead Conductor Clearances
- 680.10Underground Wiring Location
- Table 680.10Minimum Cover Depths
- 680.11Equipment Rooms and Pits
- 680.12Maintenance Disconnecting Means
- 680.13Maintenance Disconnecting Means
- 680.14Wiring Methods in Corrosive Environment
- 680.20General
- 680.21Motors
- 680.22Lighting, Receptacles, and Equipment (Pools)
- 680.23Underwater Luminaires
- 680.24Junction Boxes and Electrical Enclosures for Transformers or Ground-Fault Circuit Interrupters
- 680.25Feeders
- 680.26Equipotential Bonding
- 680.27Specialized Pool Equipment
- 680.28Gas-Fired Water Heater
- 680.30General
- 680.31Pumps
- 680.32Ground-Fault Circuit Interrupters Required
- 680.33Luminaires
- 680.34Receptacle Locations
- 680.35Storable and Portable Immersion Pools
- 680.40General
- 680.41Emergency Switch for Spas and Hot Tubs
- 680.42Outdoor Installations
- 680.43Indoor Installations
- 680.44Protection
- 680.45Permanently Installed Immersion Pools
- 680.50General
- 680.51Luminaires, Submersible Pumps, and Other Submersible Equipment
- 680.52Junction Boxes and Other Enclosures
- 680.53Bonding
- 680.54Grounding
- 680.55Methods of Grounding
- 680.56Cord-and-Plug-Connected Equipment
- 680.57Signs
- 680.58GFCI Protection for Adjacent Receptacle Outlets
- 680.59GFCI Protection for Permanently Installed Nonsubmersible Pumps
- 680.60General
- 680.61Permanently Installed Therapeutic Pools
- 680.62Therapeutic Tubs (Hydrotherapeutic Tanks)
- 680.70General
- 680.71Protection
- 680.72Other Electrical Equipment
- 680.73Accessibility
- 680.74Bonding
- 680.80General
- 680.81Equipment Approval
- 680.82Protection
- 680.83Bonding
- 680.84Switching Devices and Receptacles
- 680.85Nameplate Marking
- Figure 680.8Clearances from Pool Structures
Practice questions (4)
1.For a permanently installed pool, at least one 125-volt, 15- or 20-ampere receptacle shall be located not less than 6 ft and not more than 20 ft from the inside wall of the pool, per 680.22(A).
2.Pool pump motors and other 680.21 equipment generally require GFCI protection.
3.An equipotential bonding grid (copper conductor, reinforcing steel, or listed systems) bonds the pool structure, metal fittings, and the perimeter surface per 680.26.
4.Underground wiring for a pool, measured from the inside wall, generally shall not be installed under the pool or within 5 ft unless the wiring is necessary to supply pool equipment and is in a listed raceway as 680.11 permits.
Pictures

680.2 · Publications (NSCEP)

680.1 · 680.1 Scope

680.2 · The definitions in this section apply only within this article.

680.2 · An ornamental structure or recreational water feature from

680 · A voltage not exceeding the following values

680.2 · Which one or more jets or streams of water are discharged into the

680 · Hydromassage Bathtub. A permanently installed bathtub with a recir

680.2 · Permanently Installed Swimming, Wading, Immersion, and

680.2 · Pools constructed in the ground or partially in the ground,

680.2 · The highest level water

680.7 · A luminaire intended to be installed in a forming shell

680.7 · Bonding and Equipment Grounding Terminals
Article 680 chat
- No messages yet — start the conversation.