Summary

Pools/spas — equipotential bonding, clearances for lights/receptacles, GFCI, and underwater luminaires.

Top residential exam article.

  • Equipotential bonding grid is not the same as equipment grounding alone.
  • Receptacle distances from pool walls are fixed exam numbers.
  • Underwater lights have low-voltage and GFCI rules.

Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.

Sections in Code Lookup (64)

Practice questions (4)

  1. 1.For a permanently installed pool, at least one 125-volt, 15- or 20-ampere receptacle shall be located not less than 6 ft and not more than 20 ft from the inside wall of the pool, per 680.22(A).

  2. 2.Pool pump motors and other 680.21 equipment generally require GFCI protection.

  3. 3.An equipotential bonding grid (copper conductor, reinforcing steel, or listed systems) bonds the pool structure, metal fittings, and the perimeter surface per 680.26.

  4. 4.Underground wiring for a pool, measured from the inside wall, generally shall not be installed under the pool or within 5 ft unless the wiring is necessary to supply pool equipment and is in a listed raceway as 680.11 permits.