Electric Vehicle Power Transfer System
Summary
Article 625 covers electric vehicle power transfer systems (EVSE) — branch circuits, disconnects, ventilation (legacy), load management, and personnel protection where required.
This is the primary article for EV chargers — not Article 620 (elevators / escalators).
- EVSE usually needs a dedicated branch circuit.
- Output cable is part of the listed system.
- Energy management may allow demand factoring under rules.
- Start at 625.1 Scope, then supply equipment and disconnect rules.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (40)
- 625.1Scope — Electric Vehicle Power Transfer System
- 625.2Definitions
- 625.3Other Articles
- 625.4Voltages
- 625.5Listed or Labeled
- 625.9Electric Vehicle Coupler
- 625.13Electric Vehicle Supply Equipment
- 625.14Rating
- 625.15Markings
- 625.16Means of Coupling
- 625.17Cable
- 625.18Interlock
- 625.19Automatic De-Energization of Cable
- 625.21Overcurrent Protection
- 625.22Personnel Protection System
- 625.23Disconnecting Means
- 625.25Loss of Primary Source
- 625.26Interactive Systems
- 625.28Hazardous (Classified) Locations
- 625.29Indoor Sites
- Table 625.29(D)(1)Minimum Ventilation Required in Cubic Meters per Minute (m3/min) for Each of the Total Number of Electric Vehicles That Can Be Charged at One Time
- Table 625.29(D)(2)Minimum Ventilation Required in Cubic Feet per Minute (cfm) for Each of the Total Number of Electric Vehicles That Can Be Charged at One Time
- 625.30Outdoor Sites
- 625.40Electric Vehicle Branch Circuit
- 625.41Overcurrent Protection
- 625.42Rating
- 625.43Disconnecting Means
- 625.44Equipment Connection
- 625.46Loss of Primary Source
- 625.47Multiple Feeder or Branch Circuits
- 625.48Interactive Systems
- 625.50Location
- 625.52Ventilation
- Table 625.52(B)(1)(a)Minimum Ventilation Required in Cubic Meters per Minute (m3/min) for Each of the Total Number of Electric Vehicles That Can Be Charged at One Time
- Table 625.52(B)(1)(b)Minimum Ventilation Required in Cubic Feet per Minute (cfm) for Each of the Total Number of Electric Vehicles That Can Be Charged at One Time
- 625.54Ground-Fault Circuit-Interrupter Protection for Personnel
- 625.56Receptacle Enclosures
- 625.60AC Receptacle Outlets Used for EVPE
- 625.101Grounding
- 625.102Installation
Practice questions (2)
1.Electric vehicle supply equipment (EVSE) overcurrent protection is generally sized at not less than 125% of the maximum load of the equipment per 625.41 / 625.42 continuous-load rules.
2.A 40-ampere EVSE (32 A continuous charge) generally requires a 40 A branch circuit if the EVSE is marked as using the 125% inside its rating, or a 40 A breaker on a 40 A-rated EVSE listed for that protection — always follow the nameplate.