Elevators, Dumbwaiters, Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts
Summary
Elevator feeders, disconnects, machine rooms, and standby power interfaces.
- Dedicated disconnects and working clearances.
- Fire service and emergency power coordination.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (44)
- 620.1Scope
- 620.2Definitions
- 620.3Voltage Limitations
- 620.4Live Parts Enclosed
- 620.5Working Clearances
- 620.6Ground-Fault Circuit-Interrupter Protection for Personnel
- 620.11Insulation of Conductors
- 620.12Minimum Size of Conductors
- 620.13Feeder and Branch-Circuit Conductors
- 620.14Feeder Demand Factor
- Table 620.14Feeder Demand Factors for Elevators
- 620.15Motor Controller Rating
- 620.16Short-Circuit Current Rating
- 620.21Wiring Methods
- 620.22Branch Circuits for Car Lighting, Receptacle(s), Ventilation, Heating, and Air-Conditioning
- 620.23Branch Circuits for Machine Room or Control Room/Machinery Space or Control Space Lighting and Receptacle(s)
- 620.24Branch Circuit for Hoistway Pit Lighting and Receptacle(s)
- 620.25Branch Circuits for Other Utilization Equipment
- 620.32Metal Wireways and Nonmetallic Wireways
- 620.33Number of Conductors in Raceways
- 620.34Supports
- 620.35Auxiliary Gutters
- 620.36Different Systems in One Raceway or Traveling Cable
- 620.37Wiring in Hoistways, Machine Rooms, Control Rooms, Machinery Spaces, and Control Spaces
- 620.38Electrical Equipment in Garages and Similar Occupancies
- 620.41Suspension of Traveling Cables
- 620.42Hazardous (Classified) Locations
- 620.43Location of and Protection for Cables
- 620.44Installation of Traveling Cables
- 620.51Disconnecting Means
- 620.52Power from More Than One Source
- 620.53Car Light, Receptacle(s), and Ventilation Disconnecting Means
- 620.54Heating and Air-Conditioning Disconnecting Means
- 620.55Utilization Equipment Disconnecting Means
- 620.61Overcurrent Protection
- 620.62Selective Coordination
- 620.65Signage
- 620.71Guarding Equipment
- 620.81Metal Raceways Attached to Cars
- 620.82Electric Elevators
- 620.83Nonelectric Elevators
- 620.84Escalators, Moving Walks, Platform Lifts, and Stairway Chairlifts
- 620.85Ground-Fault Circuit-Interrupter Protection for Personnel
- 620.91Emergency and Standby Power Systems
Practice questions (1)
1.Article 620 covers elevators, dumbwaiters, escalators, moving walks, platform lifts, and stairway chairlifts — including a dedicated disconnecting means in sight of the controller.
Pictures

620.14 · Part Ill. Wiring

620.13 · 1 5A and 20A, 125V receptacles in machine

620.24 · Elevator

620.23 · At least one 125V, single-phase, 15A or

620.6 · The required lighting in these spaces is not permitted to be connected

620.37 · The disconnect must be listed and be an enclosed

620.6 · At least one 1 5A or 20A, 1 25V

620.37 · Only wiring, raceways, and cables