Marinas, Boatyards, Floating Buildings, and Commercial and Noncommercial Docking Facilities
Summary
Marina shore power — GFCI/GFP, isolation, and corrosion.
- Shore power GFCI thresholds have tightened in later years.
- Equipotential and corrosion control matter.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (36)
- 555.1Scope
- 555.2Definitions
- 555.3Electrical Datum Plane Distances
- 555.4Distribution System
- 555.5Transformers
- 555.6Load Calculations for Service and Feeder Conductors
- Table 555.6Demand Factors
- 555.7Location of Service Equipment
- 555.8Marine Hoists, Railways, Cranes, and Monorails
- 555.9Electrical Connections
- 555.10Electrical Equipment Enclosures
- 555.11Circuit Breakers, Switches, Panelboards, and Marine Power Outlets
- 555.12Load Calculations for Service and Feeder Conductors
- Table 555.12Demand Factors
- 555.13Wiring Methods and Installation
- 555.15Grounding
- 555.17Disconnecting Means for Shore Power Connection(s)
- 555.19Receptacles
- 555.21Motor Fuel Dispensing Stations — Hazardous (Classified) Locations
- 555.22Repair Facilities — Hazardous (Classified) Locations
- 555.23Marine Hoists, Railways, Cranes, and Monorails
- 555.30Electrical Connections
- 555.31Electrical Equipment Enclosures
- 555.32Circuit Breakers, Switches, Panelboards, and Marina Power Outlets
- 555.33Receptacles
- 555.34Wiring Methods and Installation
- 555.35Ground-Fault Protection of Equipment (GFPE) and Ground-Fault Circuit-Interrupter (GFCI) Protection
- 555.36Disconnecting Means for Shore Power Connection(s)
- 555.37Equipment Grounding Conductor
- 555.50Service Conductors
- 555.51Feeder Conductors
- 555.52Installation of Services and Feeders
- 555.53Ground-Fault Protection
- 555.54Grounding
- 555.55Insulated Neutral
- 555.56Equipment Grounding
Practice questions (0)
No practice questions tagged to Article 555 yet.
Pictures

555.2 · Electrical Datum Plane

555.2 · Pier, Fixed (Fixed Pier). A pier constructed on a permanent, fixed

555.2 · Shore Power. The electrical equipment required to power a floating

555.2 · Article 100 Definition

555.2 · A pier constructed on a permanent, fixed foundation.

555.3 · In land areas subject to tidal fluctuation. the electrical

555.2 · Article 100 Definition

555.2 · The electrical datum plane is a horizontal plane

555.3 · Electrical_Datum Plane

555.6 · Pier power distribution systems must not exceed 250V phase to phase.

555.7 · A permanent safety sign is required to give notice of electrical shock

555.1 · WARNING-POTENTIAL SHOCK HAZARD-ELECTRICAL
Article 555 chat