Summary
Hospitals and health care — patient care spaces, equipotential grounding, isolated power, essential electrical systems.
Major exam article for journey-level and specialized tests.
- Patient care space has stricter grounding/bonding.
- Essential systems (life safety, critical, equipment) have transfer rules.
- Limited wet procedure locations and isolated power panels appear on exams.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (51)
- 517.1Scope
- 517.2Definitions
- 517.10Applicability
- 517.11General Installation — Construction Criteria
- 517.12Wiring Methods
- 517.13Equipment Grounding Conductor for Receptacles and Fixed Equipment in Patient Care Spaces
- 517.14Panelboard Bonding
- 517.16Receptacles with Insulated Grounding Terminals
- 517.17Ground-Fault Protection
- 517.18General Care (Category 2) Spaces — Receptacles
- 517.19Critical Care (Category 1) Spaces
- 517.20Wet Procedure Locations
- 517.21Ground-Fault Circuit-Interrupter Protection for Personnel
- 517.25Scope
- 517.26Application of Other Articles
- 517.29Type 1 Essential Electrical Systems
- 517.30Essential Electrical Systems for Hospitals
- 517.31Emergency System
- 517.32Life Safety Branch
- 517.33Critical Branch
- 517.34Equipment System Connection to Alternate Power Source
- 517.35Sources of Power
- 517.40Essential Electrical Systems for Nursing Homes and Limited Care Facilities
- 517.41Essential Electrical Systems
- 517.42Automatic Connection to Life Safety Branch
- 517.43Connection to Critical Branch
- 517.44Sources of Power
- 517.45Essential Electrical Systems for Other Health Care Facilities
- 517.60Anesthetizing Location Classification
- 517.61Wiring and Equipment
- 517.62Grounding
- 517.63Grounded Power Systems in Anesthetizing Locations
- 517.64Low-Voltage Equipment and Instruments
- 517.70Applicability
- 517.71Connection to Supply Circuit
- 517.72Disconnecting Means
- 517.73Rating of Supply Conductors and Overcurrent Protection
- 517.74Control Circuit Conductors
- 517.75Equipment Installations
- 517.76Transformers and Capacitors
- 517.77Installation of High-Tension X-Ray Cables
- 517.78Guarding and Grounding
- 517.80Patient Care Areas
- 517.81Other-Than-Patient-Care Areas
- 517.82Signal Transmission Between Appliances
- 517.160Isolated Power Systems
- 517.PartVPart V. X-Ray Installations — Introduction
- FPN Figure 517.30, No. 1Hospital — Minimum Requirement for Transfer Switch Arrangement
- FPN Figure 517.30, No. 2Hospital — Minimum Requirement (150 kVA or less) for Transfer Switch Arrangement
- FPN Figure 517.41, No. 1Nursing Home and Limited Health Care Facilities — Minimum Requirement for Transfer Switch Arrangement
- FPN Figure 517.41, No. 2Nursing Home and Limited Health Care Facilities — Minimum Requirement (150 kVA or less) for Transfer Switch Arrangement
Practice questions (2)
1.Health care facilities (Article 517) require a patient-care space wiring method that provides a redundant grounding path (typically metal raceway or a cable with an insulated EGC plus metallic armor/sheath listed as an EGC).
2.Hospital-grade receptacles are required in patient bed locations in general care and critical care spaces per 517.18 / 517.19.
Pictures

517.1 · Nursing Home. A building or an area of a building used for the

517.2 · Health Care Facilities. Buildings, portions of buildings, or mobile

517.2 · Patient Care

517.2 · FMC 6 ft '"' ·· l.·,,,u . ,

517.2 · The metal sheath of Type AC cable is identified as an

517.2 · The metal sheath of Type MCAP® cable (metal-clad

517.2 · The metal sheath of Type AC cable is identified as an

517.2 · Metal enclosures containing

517.2 · Noncurrent-carrying metal parts of fixed

517.1 · Health Care Facilities, Patient Care Spaces, Insulated EGCs

517.13 · Health Care Facilities, Patient Care Spaces

517.2 · Noncurrent-carrying metal parts of fixed
Article 517 chat
- No messages yet — start the conversation.