Switchboards, Switchgear, and Panelboards
Summary
Panelboard/switchboard installation, overcurrent protection, circuit directory, and working clearances coordination with 110.26.
- Circuit directory must be clear and up to date.
- Panelboard overcurrent protection rules differ by type.
- Unused openings must be closed.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (33)
- 408.1Scope
- 408.2Other Articles
- 408.3Support and Arrangement of Busbars and Conductors
- 408.4Field Identification Required (Panel Directories)
- 408.5Clearance for Conductor Entering Bus Enclosures
- Table 408.5Clearance for Conductors Entering Bus Enclosures
- 408.6Short-Circuit Current Rating
- 408.7Unused Openings
- 408.8Reconditioning of Equipment
- 408.16Switchboards in Damp or Wet Locations
- 408.17Location Relative to Easily Ignitible Material
- 408.18Clearances
- 408.19Conductor Insulation
- 408.20Location of Switchboards
- 408.22Grounding of Instruments, Relays, Meters, and Instrument Transformers on Switchboards
- 408.23Power Monitoring and Energy Management Equipment
- 408.30General
- 408.36Overcurrent Protection
- 408.37Panelboards in Damp or Wet Locations
- 408.38Enclosure
- 408.39Relative Arrangement of Switches and Fuses
- 408.40Grounding of Panelboards
- 408.41Grounded Conductor Terminations
- 408.43Panelboard Orientation
- 408.50Panels
- 408.51Busbars
- 408.52Protection of Instrument Circuits
- 408.53Component Parts
- 408.54Maximum Number of Overcurrent Devices
- 408.55Wire-Bending Space in Panelboards
- 408.56Minimum Spacings
- Table 408.56Minimum Spacings Between Bare Metal Parts
- 408.58Panelboard Marking
Practice questions (2)
1.A panelboard is protected on the supply side by not more than one overcurrent device unless 408.36 exceptions apply (for example a main breaker in the panel, or a main-lug panel fed by a single OCPD).
2.Unused openings in panelboards, including spaces for circuit breakers, shall be closed with identified closures.
Pictures

408.1 · Switchboards and Panelboards

408.3 · Phase Arrangement

408.3 · The high-leg must

408.4 · Switchboards, switchgear, or

408.4 · All circuits and circuit modifications must be legibly

408.5 · Kit. Lights

408.4 · Field Identification

408.4 · NC - Heat

408.7 · Unused Openings

408.18 · Connections :;i, , , '

408.36 · Overcurrent Protection

408.40 · Metal cabinets containing panel boards must be connected to an equip