Receptacles, Cord Connectors, and Attachment Plugs
Summary
Receptacle ratings, tamper-resistant, weather-resistant, GFCI devices, and replacement rules.
TR receptacles in dwellings and WR outdoor devices are frequent questions.
- Receptacle rating must match circuit rules in 210.21.
- Tamper-resistant required in many dwelling areas.
- Weather-resistant + in-use covers outdoors where required.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (15)
- 406.1Scope
- 406.2Receptacle Rating and Type
- 406.3General Installation Requirements
- 406.4General Installation Requirements (Receptacles)
- 406.5Receptacle Faceplates (Cover Plates)
- 406.6Attachment Plugs, Cord Connectors, and Flanged Surface Devices
- 406.7Noninterchangeability
- 406.8Receptacles in Damp or Wet Locations
- 406.9Grounding-Type Receptacles, Adapters, Cord Connectors, and Attachment Plugs
- 406.10Connecting Receptacle Grounding Terminal to Box
- 406.11Tamper-Resistant Receptacles in Dwelling Units
- 406.12Tamper-Resistant Receptacles
- 406.13Single-Pole Separable-Connector Type
- Figure 406.3(E)Controlled Receptacle Marking Symbol
- Informational Note Figure 406.10(B)(4)One Example of a Symbol Used to Identify the Termination Point for an Equipment Grounding Conductor
Practice questions (3)
1.Receptacles shall be of the grounding type where installed on 15- and 20-ampere branch circuits, except as permitted in 406.4.
2.When replacing a nongrounding receptacle where an equipment grounding conductor does not exist in the outlet, 406.4(D) generally permits a GFCI receptacle marked “No Equipment Ground,” or a grounding receptacle supplied through a GFCI and marked “GFCI Protected” and “No Equipment Ground.”
3.Tamper-resistant receptacles are required in dwelling units for 15- and 20-ampere 125-volt receptacles as listed in 406.12.
Pictures

406.1 · Article 406 covers the rating, type,

406.1 · A housing shield (hood) over a faceplate for flush

406.4 · Receptacles of the isolated equipment grounding

406.4 · The metal yoke is

406.4 · Receptacles of the isolated equipment grounding

406.4 · The controlled/power symbol marking isn't required

406.1 · The EGC contacts of receptacles

406.4 · Self-Grounding Type

406.4 · Table 21 0.21 (8)(3) permits both 1 5A and

406.4 · Receptacle Installation

406.4 · Where a nongrounding-type receptacle is replaced

406.4 · With • -;i;.;a