Flexible Cords and Flexible Cables
Summary
Cord types, ampacity, uses not permitted (substituting for fixed wiring), and strain relief.
- Cords are not a substitute for permanent wiring.
- Types (SO, SJ, etc.) and ampacity tables appear on exams.
- Hard usage vs junior hard usage distinctions.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (36)
- 400.1Scope
- 400.2Other Articles
- 400.3Suitability
- 400.4Types
- Table 400.4Flexible Cords and Cables (See 400.4.)
- 400.5Ampacities for Flexible Cords and Cables
- Table 400.5Adjustment Factors for More Than Three Current-Carrying Conductors in a Flexible Cord or Cable
- Table 400.5(A)Allowable Ampacity for Flexible Cords and Cables
- Table 400.5(A)(1)Ampacity for Flexible Cords and Flexible Cables
- Table 400.5(A)(2)Ampacity of Cable Types SC, SCE, SCT, PPE, G, G-GC, and W
- Table 400.5(A)(3)Adjustment Factors for More Than Three Current-Carrying Conductors in a Flexible Cord or Flexible Cable
- Table 400.5(B)Ampacity of Cable Types SC, SCE, SCT, PPE, G, G-GC, and W
- 400.6Markings
- 400.7Uses Permitted
- 400.8Uses Not Permitted
- 400.9Splices
- 400.10Pull at Joints and Terminals
- 400.11In Show Windows and Showcases
- 400.12Minimum Size
- 400.13Overcurrent Protection
- 400.14Protection from Damage
- 400.15In Show Windows and Showcases
- 400.16Overcurrent Protection
- 400.17Protection from Damage
- 400.20Labels
- 400.21Nominal Insulation Thickness
- 400.22Grounded-Conductor Identification
- 400.23Equipment Grounding Conductor Identification
- 400.24Attachment Plugs
- 400.30Scope
- 400.31Construction
- 400.32Shielding
- 400.33Equipment Grounding Conductors
- 400.34Minimum Bending Radii
- 400.35Fittings
- 400.36Splices and Terminations
Practice questions (1)
1.Flexible cords are not a substitute for the fixed wiring of a structure except as permitted in 400.10 (pendants, portable lamps, appliances, cranes, etc.).
Pictures

400.4 · Flexible cords and flexible cables, as well as their

400.4 · Flexible cords and flexible cables, as well as their

400.4 · Types

400.1 · Flexible cords can be used to connect utilization

400.10 · Flexible Cords, Uses Permitted

400.1 · Appliance

400.5 · A flexible cord can be used for appliances where the fastening

400.14 · VIOLATION

400.14 · Or located

400.14 · Flexible cords must be installed

400.14 · Pull at Joints and Terminals

400.14 · Tension relief can be accomplished by knotting
Article 400 chat
- No messages yet — start the conversation.