Summary
OCPD selection, standard ampere ratings, tap rules, location of protection, and series ratings basics.
Tap rules (240.21) and conductor/OCPD coordination are classic exam traps.
- OCPD protects conductors and equipment within ratings.
- Standard breaker sizes must be memorized for exams.
- Tap rules allow limited unprotected lengths when conditions are met.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (48)
- 240.1Scope
- 240.2Definitions
- 240.3Other Articles
- Table 240.3Other Articles
- 240.4Protection of Conductors
- Table 240.4(G)Specific Conductor Applications
- 240.5Protection of Flexible Cords, Flexible Cables, and Fixture Wires
- 240.6Standard Ampere Ratings
- Table 240.6(A)Standard Ampere Ratings for Fuses and Inverse Time Circuit Breakers
- 240.8Fuses or Circuit Breakers in Parallel
- 240.9Thermal Devices
- 240.10Supplementary Overcurrent Protection
- 240.12Electrical System Coordination
- 240.13Ground-Fault Protection of Equipment
- 240.15Ungrounded Conductors
- 240.21Location in Circuit (Tap Rules)
- 240.22Grounded Conductor
- 240.23Change in Size of Grounded Conductor
- 240.24Location in or on Premises
- 240.30General
- 240.32Damp or Wet Locations
- 240.33Vertical Position
- 240.40Disconnecting Means for Fuses
- 240.41Arcing or Suddenly Moving Parts
- 240.50General
- 240.51Edison-Base Fuses
- 240.52Edison-Base Fuseholders
- 240.53Type S Fuses
- 240.54Type S Fuses, Adapters, and Fuseholders
- 240.60General
- 240.61Classification
- 240.62Reconditioned Equipment
- 240.67Arc Energy Reduction
- 240.80Method of Operation
- 240.81Indicating
- 240.82Nontamperable
- 240.83Marking
- 240.85Applications
- 240.86Series Ratings
- 240.87Arc Energy Reduction
- 240.88Reconditioned Equipment
- 240.90General
- 240.91Protection of Conductors
- 240.92Location in Circuit
- Table 240.92(B)Tap Conductor Short-Circuit Current Ratings
- 240.100Feeders and Branch Circuits
- 240.101Additional Requirements for Feeders
- 240.102Reconditioned Equipment
Practice questions (18)
1.Conductors shall be protected against overcurrent in accordance with their ampacities as specified in 310.14, unless otherwise permitted or required in 240.4.
2.Small conductor rules in 240.4(D) generally limit overcurrent protection for 14 AWG copper to _____ unless otherwise permitted.
3.For 12 AWG copper, 240.4(D) generally limits overcurrent protection to _____ unless otherwise permitted.
4.For 10 AWG copper, 240.4(D) generally limits overcurrent protection to _____ unless otherwise permitted.
5.Tap conductors are permitted under the conditions of 240.21, including the 10-ft and 25-ft tap rules where all listed conditions are met.
Pictures

240.83 · Overcurrent protective devices, such as circuit breakers and fuses,

240.6 · Feeder overcurrent devices must have an ampacity

240.2 · Fault Current

240.4 · Service Conductors

240.4 · Except as permitted by (A) through (G),

240.4 · Table 31 0.1 6 contains conductor ampacities based on up

240.4 · If the circuit's overcurrent device exceeds

240.4 · Overcurrent Protective Devices

240.4 · KC:::=L-=:::: 1 2 AWG Conductor

240.4 · Air-conditioning and refrigeration equipment must be

240.4 · Motor circuit conductors must be protected against short

240.6 · The standard ratings for fuses and inverse-time
Article 240 chat
- No messages yet — start the conversation.