Outside Branch Circuits and Feeders
Summary
Outdoor branch circuits and feeders: clearances, supports, disconnects, and wiring methods outside buildings.
Often tested with overhead clearances and building disconnect locations.
- Outside feeders need proper support and clearances.
- Building disconnect rules differ from indoor panels.
- Weatherproofing and outdoor-rated equipment matter.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (45)
- 225.1Scope
- 225.2Other Articles
- Table 225.2Other Articles
- 225.3Calculation of Loads 600 Volts, Nominal, or Less
- Table 225.3Other Articles
- 225.4Conductor Covering
- 225.5Size of Conductors 600 Volts, Nominal, or Less
- 225.6Conductor Size and Support
- 225.7Lighting Equipment Installed Outdoors
- 225.10Wiring on Buildings
- 225.11Circuit Exits and Entrances
- 225.12Open-Conductor Supports
- 225.14Open-Conductor Spacings
- 225.15Supports over Buildings
- 225.16Attachment to Buildings
- 225.17Masts as Supports
- 225.18Clearance for Overhead Conductors and Cables
- 225.19Clearances from Buildings for Conductors of Not over 600 Volts, Nominal
- 225.20Mechanical Protection of Conductors
- 225.21Multiconductor Cables on Exterior Surfaces of Buildings
- 225.22Raceways on Exterior Surfaces of Buildings or Other Structures
- 225.24Outdoor Lampholders
- 225.25Location of Outdoor Lamps
- 225.26Vegetation as Support
- 225.27Raceway Seal
- 225.30Number of Supplies
- 225.31Disconnecting Means (Outside Branch Circuits/Feeders)
- 225.32Location
- 225.33Maximum Number of Disconnects
- 225.34Grouping of Disconnects
- 225.35Access to Occupants
- 225.36Suitable for Service Equipment
- 225.37Identification
- 225.38Disconnect Construction
- 225.39Rating of Disconnect
- 225.40Access to Overcurrent Protective Devices
- 225.50Sizing of Conductors
- 225.51Isolating Switches
- 225.52Location
- 225.53Type
- 225.56Inspections and Tests
- 225.60Clearances over Roadways, Walkways, Rail, Water, and Open Land
- Table 225.60Clearances over Roadways, Walkways, Rail, Water, and Open Land
- 225.61Clearances over Buildings and Other Structures
- Table 225.61Clearances over Buildings and Other Structures
Practice questions (0)
No practice questions tagged to Article 225 yet.
Pictures

225.6 · Underground Branch Circuit or Feeder

225.6 · Underground Branch Circuit or Feeder

225.1 · Open conductors without a messenger wire

225.16 · Minimum 1 0 AWG for

225.6 · The point of attachment must also be located so the minimum

225.17 · VIOLATION: Conductors cannot

225.16 · Customer

225.16 · Overhead conductors must have a minimum clearance

225.19 · Overhead Conductor Clearance

225.19 · Overhead Conductor Clearance, Above Roof

225.19 · Overhead conductor spans must maintain a vertical

225.19 · Overhead conductors must not be installed under an