Branch-Circuit, Feeder, and Service Load Calculations
Summary
Load calculation methods for dwellings and other occupancies — general lighting, receptacles, appliances, HVAC, demand factors, and optional calculations.
Exam staple: standard method vs optional dwelling calculation; continuous loads at 125%; demand factors on general lighting.
- Continuous loads: size conductors and OCPD for 125% unless exception.
- Apply demand factors only where the Code allows.
- Service/feeder size follows calculated load after demand factors.
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (46)
- 220.1Scope
- 220.3Application of Other Articles
- Table 220.3Additional Load Calculation References
- 220.5Calculations
- 220.10General
- 220.11Floor Area
- 220.12Lighting Load for Specified Occupancies
- Table 220.12General Lighting Loads by Occupancy
- 220.14Other Loads — All Occupancies
- 220.16Loads for Additions to Existing Installations
- 220.18Maximum Loads
- 220.40General
- 220.42General Lighting
- Table 220.42Lighting Load Demand Factors
- 220.43Show-Window and Track Lighting
- 220.44Receptacle Loads — Other Than Dwelling Units
- Table 220.44Demand Factors for Non-Dwelling Receptacle Loads
- 220.50Motors
- 220.51Fixed Electric Space Heating
- 220.52Small-Appliance and Laundry Loads — Dwelling Unit
- 220.53Appliance Load — Dwelling Unit(s)
- 220.54Electric Clothes Dryers — Dwelling Unit(s)
- Table 220.54Demand Factors for Household Electric Clothes Dryers
- 220.55Electric Ranges and Cooking Appliances
- Table 220.55Demand Factors and Loads for Household Electric Ranges, Wall-Mounted Ovens, Counter-Mounted Cooking Units, and Other Household Cooking Appliances over 1 3/4 kW Rating
- 220.56Kitchen Equipment — Other Than Dwelling Unit(s)
- Table 220.56Demand Factors for Kitchen Equipment — Other Than Dwelling Unit(s)
- 220.60Noncoincident Loads
- 220.61Feeder or Service Neutral Load
- 220.80General
- 220.82Optional Calculation — Dwelling Unit
- 220.83Existing Dwelling Unit
- 220.84Multifamily Dwelling
- Table 220.84Optional Calculations — Demand Factors for Three or More Multifamily Dwelling Units
- 220.85Two Dwelling Units
- 220.86Schools
- Table 220.86Optional Method — Demand Factors for Feeders and Service Conductors for Schools
- 220.87Determining Existing Loads
- 220.88New Restaurants
- Table 220.88Optional Method — Permitted Load Calculations for Service and Feeder Conductors for New Restaurants
- 220.100General
- 220.102Farm Loads — Buildings and Other Loads
- Table 220.102Method for Calculating Farm Loads for Other Than Dwelling Unit
- 220.103Farm Loads — Total
- Table 220.103Method for Calculating Total Farm Load
- Figure 220.1Branch-Circuit, Feeder, and Service Calculation Methods
Practice questions (24)
1.Article 220 provides requirements for calculating branch-circuit, feeder, and service loads.
2.Unless otherwise permitted, for continuous loads the calculated load is based on _____ of the continuous load.
3.Floor area for dwelling unit general lighting load calculations is computed from the outside dimensions of the building, dwelling unit, or other area involved.
4.The general lighting load for dwelling units in Table 220.12 is based on volt-amperes per square meter (or square foot).
5.For dwelling-unit feeder/service calculations, the small-appliance and laundry loads are added at _____ each before demand factors in Part III methods as applicable.
Pictures

220.5 · SSBJ: Supply-Side Bonding Jumper

220.5 · Rounding Fractions of Amperes

220.5 · Nominal Voltage

220.1 · Part IV. Optional

220.11 · Floor area is calculated from the outside dimensions

220.5 · Floor area is calculated from the outside dimensions

220.12 · Outside Dimension ---->l

220.14 · Sign Outlets, Commercial Buildings

220.14 · 50 Linear Ft of Show-Window Lighting

220.10 · Fixed multioutlet assemblies in commercial occupancies

220.12 · Fixed multioutlet assemblies in commercial occupancies

220.14 · Two Straps