Summary
Branch-circuit rules for ratings, multiwire circuits, GFCI/AFCI, receptacle placement, and required outlets in dwellings and other occupancies.
210.8 GFCI and 210.12 AFCI lists change by Code year — always match the book year of the exam.
- Branch circuit ends at the final OCPD protecting outlets.
- GFCI = personnel shock; AFCI = fire from arcing.
- Dwelling receptacle layout has many fixed rules (kitchen, bath, laundry, outdoor).
Study notes from the app's code library — always confirm with the official NEC book your AHJ adopts.
Sections in Code Lookup (41)
- 210.1Scope
- 210.2Other Articles for Specific-Purpose Branch Circuits
- Table 210.2Specific-Purpose Branch Circuits
- 210.3Rating
- Table 210.3Specific-Purpose Branch Circuits
- 210.4Multiwire Branch Circuits
- 210.5Identification for Branch Circuits
- 210.6Branch-Circuit Voltage Limitations
- 210.7Branch-Circuit Requirements for Device Connections and Locations
- 210.8Ground-Fault Circuit-Interrupter Protection for Personnel
- 210.9Circuits Derived from Autotransformers
- 210.10Ungrounded Conductors Tapped from Grounded Systems
- 210.11Branch Circuits Required
- 210.11(C)(1)Small-Appliance Branch Circuits Required
- 210.11(C)(3)Bathroom Branch Circuits Required
- 210.12Arc-Fault Circuit-Interrupter Protection
- 210.13Ground-Fault Protection of Equipment
- 210.15Reconditioned Equipment
- 210.17Guest Rooms and Guest Suites
- 210.18Guest Rooms and Guest Suites
- 210.19Conductors — Minimum Ampacity and Size
- 210.20Overcurrent Protection
- 210.21Outlet Devices
- Table 210.21(B)(2)Maximum Cord-and-Plug-Connected Load to Receptacle
- Table 210.21(B)(3)Receptacle Ratings for Various Size Circuits
- 210.22Permissible Loads, Individual Branch Circuits
- 210.23Permissible Loads — Branch Circuits
- 210.24Branch-Circuit Requirements — Summary
- Table 210.24Summary of Branch-Circuit Requirements
- 210.25Branch Circuits in Buildings with More Than One Occupancy
- 210.50General
- 210.52Dwelling Unit Receptacle Outlets
- 210.52(B)Small-Appliance Branch Circuits (Dwelling Unit)
- 210.52(B)(1)SABC Receptacle Outlets Served
- 210.52(B)(2)SABC — No Other Outlets
- 210.52(D)Bathrooms — Receptacle Placement
- 210.60Guest Rooms, Guest Suites, Dormitories, and Similar Occupancies
- 210.62Show Windows
- 210.63Heating, Air-Conditioning, and Refrigeration Equipment Outlet
- 210.65Meeting Rooms
- 210.70Lighting Outlets Required
Practice questions (45)
1.In dwelling units, all 125-volt through 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to ground, installed in bathrooms, require GFCI protection.
2.GFCI protection for personnel in dwelling-unit kitchens applies to receptacles:
3.When measuring whether a receptacle is within the GFCI “distance” of a sink, the Code uses:
4.Outdoor receptacles for dwelling units generally require GFCI protection.
5.Dwelling-unit bathrooms require at least one 20-ampere branch circuit to supply the bathroom receptacle outlet(s). That circuit:
Pictures

210.1 · Article 210 provides the general requirements for branch

210.1 · Branch circuit

210.4 · Multiwire Branch Circuits, General

210.1 · Article 1 00 Definition

210.4 · Multiwire Branch Circuits

210.1 · A multiwire branch circuit is permitted

210.4 · Multiwire Branch Circuits

210.4 · Multiwire Branch Circuits

210.4 · Multiwire Circuits, Grouping